Automatic 12V / 24V detection
The device can operate from both 12V and 24V battery inputs. Lower rated power is available in 12V mode and higher rated power in 24V mode.
Higher-power automatic 12/24V detection, pure sine wave 230V inverter for EnergonX PowerBox systems. It is especially useful for 24V configurations where larger 230V loads are planned.
Important: To use the full output capacity, the main fuse, main DC wiring, Anderson connector, battery cables and battery/BMS load capability must be checked at system level. On an existing EnergonX unit, main fuse, wiring or battery replacement may be required.
External pure sine wave inverter module for EnergonX PowerBox systems, with automatic 12V / 24V input detection.
The device can operate from both 12V and 24V battery inputs. Lower rated power is available in 12V mode and higher rated power in 24V mode.
The device can operate from both 12V and 24V battery inputs. Lower rated power is available in 12V mode and higher rated power in 24V mode.
It can be electrically matched with every 12V and 24V EnergonX PowerBox model, but the complete system sizing must be checked separately.
To use the full inverter capacity, the main fuse, main DC wiring, Anderson connector, battery cabling and suitable BMS load capability are required.
Power data must always be interpreted separately in 12V and 24V modes.
| Feature | 12V mode | 24V mode |
|---|---|---|
| EnergonX product code | {EX2310-INVDAT-6000W} | |
| Manufacturer model | TY-PSW-6000 | |
| Rated power | 1500 W | 3000 W |
| Peak power | 3000 W | 6000 W |
| Input voltage range | 10–15.8 V | 20–31.5 V |
| Low-voltage alarm | 10.5 V | 21 V |
| Low-voltage protection | 10 V | 20 V |
| High-voltage protection | 15.8 V / 31.5 V | |
| Overload protection | ≥1600 W / ≥3200 W | |
| Low-voltage auto recovery | 12.8 V / 25.3 V | |
| No-load current | 0.72 A / 0.6 A | |
| Loss | <10 W / <20 W | |
| Output voltage | pure sine wave output configured for 230 V use; manufacturer output mode adjustable between 220 / 230 / 240 V and 50 / 60 Hz | |
| Conversion efficiency | ≥90% | |
| USB outputs | 1 × Type-C + 1 × USB-A 5V / 2.1A | |
| External dimensions | approx. 33 × 24 × 9.5 cm | |
| Weight | approx. 3.61 kg | |
| Operating environment | -5 °C to +40 °C, max. 90% relative humidity | |
The TY-PSW-6000 provides different rated and peak output in 12V and 24V modes. Before selection, system voltage, battery BMS, main fuse, wiring and planned loads must be checked together.
The number and role of connectors are important for PowerBox compatibility and mechanical integration.
| Connector / element | Quantity and specification | EnergonX note |
|---|---|---|
| 230 V AC output | 2 front mains sockets | The physical socket standard depends on the supplied EU/230 V version. |
| DC input | 1 positive and 1 negative high-current input terminal / electrode | In EnergonX use normally supplied with a 120A Anderson connector; for CSERKÉSZ use with the 4000W model, a 50A Anderson version must be requested. |
| USB-A output | 1 USB 5V / 2.1A | For low-power USB device charging. |
| USB-C output | 1 Type-C | The manufacturer data sheet indicates Type-C output; exact PD power is not specified. |
| Cooling | 1 fan + heat-dissipation openings | The fan and vents must not be covered. |
| Display | 1 LCD display | Input/output voltage, power, capacity, frequency, waveform and alarm identification. |
A 120A or 50A Anderson connector is safe for the given current only if the complete DC current path – main fuse, battery cable, main DC wiring, connector main cables and battery/BMS – is sized accordingly.
Electrical compatibility and mechanical mountability are not the same.
The TY-PSW-6000 can be used electrically with every 12V and 24V EnergonX PowerBox model if the connection, fusing, wiring and battery are sized for the planned inverter current draw.
Due to its physical size, it can be mounted as an external module on NOMAD, KARAVÁN and EXPLORER models. With CSERKÉSZ, a separate placement and connection solution must be agreed.
For the CSERKÉSZ model this is usually not the most practical choice; the 4000W version is normally sufficient with a 50A Anderson connector.
These larger inverter modules are normally supplied with a 120A Anderson connector. When matching them to an existing or smaller EnergonX unit, the connector type and the complete DC current path must be checked separately.
A high-power inverter must not be selected based on the connector alone.
If the inverter is ordered later for a PowerBox model that has, for example, an 80A main fuse, the main fuse and the related wiring must also be reviewed and replaced if necessary.
A larger main fuse can only be used safely if the complete current path is sized for it: this may include battery cables, main fuse cables, Anderson connector main cables and other high-current DC connections.
Always ask EnergonX for support, because this modification requires a qualified professional and a system-level check.
With a larger inverter, battery compatibility is not only a voltage question. BMS continuous and peak load capability, battery capacity, wiring and the full PowerBox system must be checked together.
In an existing EnergonX unit, the built-in battery may need to be replaced if the full inverter capacity is required.
According to the manufacturer data sheet, the inverter has several basic protection and feedback functions.
Low voltage, high voltage, overload, high temperature and short-circuit protection. If the input is connected in reverse, the connection must be corrected.
The display may show input voltage, output voltage, power, capacity, frequency, waveform and alarm identification. A buzzer is also included for fault indication.
The inverter requires proper ventilation and heat dissipation. Vents must not be covered, and the device must not be operated in a closed, overheating location.
When connecting an external inverter, UPS module, mains charger, generator or any other external 230 V device, the DC-side power is not the only point to check. The grounding, protective conductor, neutral conductor and electrical-protection requirements of the given 230 V device must also be checked.
Any modification, creation or bypassing of a protective conductor, grounding, neutral conductor or N–PE bond may only be carried out by a properly qualified electrical professional. The inverter must not be modified or opened by the user.
PowerBox technical description – grounding for external inverters and 230 V modules
The correct inverter depends on the PowerBox model, system voltage, loads, battery BMS, main fuse and wiring.