EnergonX UPS Tech 12 BASE

EnergonX
EnergonX
🔋12 V / 12.8 V system 〰️1000 W pure sine wave Automatic UPS 🛡️AVR + fixed phase 🔧5–30 A charger 🧰EXPLORER frame Battery not included

EnergonX UPS Tech 12 BASE

SKU: {EX1400-EXP-12}

A fully assembled, battery-free 12 V EnergonX UPS base unit with an EXPLORER frame, an external pure sine wave UPS module, eight integrated M8 mounting points and the required EnergonX connector sets.

The external UPS module provides up to 1000 W continuous 230 V output, two sockets, automatic UPS transfer, AVR voltage regulation, fixed-phase operation and adjustable 5–30 A battery charging.

Which batteries can be used: Compatible with any 12 V AGM battery that physically fits inside the EXPLORER frame and whose manufacturer-specified charging requirements can be matched by the adjustable charging parameters of the UPS module. For a LiFePO₄ battery, physical fit and a suitable charging profile are not enough: the battery BMS must also provide sufficient continuous and short-term discharge current for the DC-side demand of the external UPS module and the connected 230 V loads.
BASE version: the unit does not include a battery. It cannot be used as an operational backup-power system until a suitable battery has been installed and the charging, warning and cut-off parameters have been configured correctly.
Brand:
EnergonX
Product code:
{EX1400-EXP-12}
268.935 HUF
Netto price: 211.760 HUF
Piece (pc)
Piece (pc)
🔋12 V / 12.8 V system 〰️1000 W pure sine wave Automatic UPS 🛡️AVR + fixed phase 🔧5–30 A charger 🧰EXPLORER frame Battery not included

EnergonX UPS Tech 12 BASE

The EnergonX UPS Tech 12 BASE is a fully assembled, battery-free 12 V EnergonX UPS base unit. It combines the mobile EXPLORER frame, the UPS EXT Tech 1000 external pure sine wave UPS module, eight integrated M8 mounting points and the required EnergonX connector sets in one system prepared for battery installation.

After a suitable battery has been installed, the system powers the connected loads and charges the battery during mains operation, then automatically switches to battery operation in the event of a power failure or significant mains-voltage deviation.

What does the BASE version mean?

The BASE version includes the external UPS module, the EXPLORER frame, mounting points and the connection and installation components required for the system, but it does not include a battery.

Not a complete backup-power system without a battery: the unit becomes an operational EnergonX UPS system only after a suitable 12 V AGM or nominal 12.8 V LiFePO₄ battery has been installed, polarity and fusing have been checked, and the charging and cut-off parameters have been configured correctly.

Main benefits

Battery-independent BASE designAn AGM or LiFePO₄ battery can be selected according to the intended use, required runtime and available budget.
1000 W pure sine wave 230 V outputWith a suitable battery, it can support sensitive electronics, controllers, circulation pumps and smaller critical loads.
Automatic UPS transferDuring a mains failure, the unit typically switches to battery operation in approximately 4 ms.
Adjustable 5–30 A chargingCharging current can be matched to battery capacity and manufacturer specifications.
AVR mains-voltage regulationCorrects moderate mains-voltage deviations without switching to battery operation.
Fixed-phase operationWith correct mains wiring, it can provide backup power for phase-sensitive boilers and controllers.
Modular EXPLORER frameThe mobile frame and eight integrated M8 mounting points provide stable installation and future expansion options.
Prepared connection systemThe QS Custom Connectors Set 3 and the dedicated UPS connector set are included in the BASE version.

System configuration

System component Description SKU / status
Frame FRAME – EXPLORER {EX-EXP-VÁZ}
External UPS module UPS EXT Tech 1000 {EX2310-UPSTech-1000}
M8 mounting point Integrated, 8 pcs {EX2100-QBRM8I}
Connector set QS Custom Connectors Set 3 {EX2100-QBRCC}
UPS connector set Accessory – UPS connector set {EX2100-UPSHT120}
Battery Not included in the BASE version Selected separately

Which batteries can be used?

Compatibility principle: Compatible with any 12 V AGM battery that physically fits inside the EXPLORER frame and whose manufacturer-specified charging requirements can be matched by the adjustable charging parameters of the UPS module. For a LiFePO₄ battery, physical fit and a suitable charging profile are not enough: the battery BMS must also provide sufficient continuous and short-term discharge current for the DC-side demand of the external UPS module and the connected 230 V loads.
12 V AGM batteryIt must physically fit inside the EXPLORER frame, the terminals and connections must remain accessible, and the manufacturer’s charging requirements must match the UPS settings.
Nominal 12.8 V LiFePO₄ batteryIn addition to physical fit, a suitable LiFePO₄ charging profile and sufficient BMS discharge capability for the intended load are required.
LiFePO₄ BMS: battery capacity alone is not sufficient. The BMS continuous and short-term discharge ratings must support the full DC-side current demand of the external UPS, including the starting peaks of connected loads.
Charging current: the selectable 5–30 A maximum charging current must always be matched to the value permitted by the battery manufacturer. A higher available setting does not mean that every battery can be charged at 30 A.
LiFePO₄ charging in cold conditions: below 0 °C, only a battery with low-temperature charging protection or an appropriate self-heating function may be charged. This protection must not be bypassed.

UPS function and 230 V power supply

The TECHTRON ZA-TECH-1000-PLUS external UPS module provides up to 1000 W of continuous pure sine wave 230 V output through two sockets. Line-Interactive operation, fast automatic transfer and four-step AVR support continuous operation of the connected loads.

The integrated three-stage charger can be set to a maximum current of 5, 10, 15, 20 or 30 A. Charging, float, warning and cut-off voltages must be configured according to the chemistry and manufacturer specifications of the installed battery.

Power and battery: the 1000 W 230 V output can be used safely only with a battery capable of supplying the necessary DC current and the required starting peaks. A LiFePO₄ battery with a lower BMS rating may limit the usable 230 V output power.

EXPLORER frame, mounting and connections

The external UPS module is integrated into one mobile system on the EXPLORER frame. The frame provides internal space prepared for battery installation, while the eight integrated M8 mounting points support stable mechanical fixing and future accessories.

The QS Custom Connectors Set 3 and the dedicated UPS connector set form part of the BASE system’s connection architecture. The accessible position of the external UPS module facilitates operation, ventilation, inspection and professional maintenance.

Modular design: a suitable battery can be selected later, replaced or changed to another capacity, provided that the new battery’s dimensions, chemistry, BMS, charging parameters and connections meet the system requirements.

Main technical specifications

The table summarises the main data for the battery-free BASE system and the installed external UPS module. Where no verified value is available, “No data” is shown.
Parameter Value Notes
SKU {EX1400-EXP-12} EnergonX BASE product item number.
Product name EnergonX UPS Tech 12 BASE “Tech” refers to the external UPS module type; “12” refers to the 12 V system voltage.
Product family EnergonX UPS EnergonX main product family supplied with an external UPS module.
Version BASE – battery not included External UPS module and mounting/connection system are installed.
System voltage 12 V / 12.8 V For a 12 V AGM or nominal 12.8 V LiFePO₄ battery.
Installed battery None A suitable battery must be selected and installed separately.
Supported battery chemistries AGM and LiFePO₄ Subject to the battery manufacturer’s charging and discharge requirements.
AGM compatibility 12 V AGM battery Must physically fit inside the EXPLORER frame and its charging requirements must match the UPS settings.
LiFePO₄ compatibility Nominal 12.8 V LiFePO₄ battery Requires physical fit, a suitable charging profile and a BMS capable of supplying the UPS current demand.
LiFePO₄ BMS requirement Continuous and short-term discharge capability suitable for the selected load The BMS must safely supply the DC-side current required by the external UPS and connected 230 V loads.
External UPS manufacturer model TECHTRON ZA-TECH-1000-PLUS UPS EXT Tech 1000.
UPS topology Line-Interactive With automatic transfer and AVR.
Continuous 230 V output power up to 1000 W System power limit when used with a suitable battery.
Rated apparent power 1500 VA Manufacturer data.
Short-term overload capability up to approx. 1200 W for a maximum of 30 seconds The UPS may then shut down.
Output waveform Pure sine wave Suitable for sensitive electronics.
230 V outputs 2 Located on the UPS module.
UPS transfer time typically approx. 4 ms, maximum 8 ms From mains to battery operation.
Return transfer time typically approx. 2 ms, maximum 4 ms After mains stability has been checked.
AVR Yes, 4-step, approx. ±8% Mains-voltage regulation.
Fixed-phase output Yes, with correct mains wiring Installation must be checked by a qualified electrician.
Integrated battery charger Three-stage intelligent charger Part of the UPS module.
Selectable maximum charging current 5 A / 10 A / 15 A / 20 A / 30 A Must be configured according to the battery manufacturer’s specifications.
Mains input voltage range approx. 160–270 V AC At extreme values, the UPS may switch to battery operation.
EXPLORER frame external dimensions 641 × 485 × 660 mm EnergonX frame data.
External UPS module dimensions approx. 34 × 17 × 38 cm The manufacturer does not specify the dimension order.
Overall system dimensions No data  
EXPLORER frame weight approx. 10.2 kg EnergonX frame data.
External UPS module weight approx. 10.5 kg Manufacturer data.
Calculated combined weight of main components approx. 20.7 kg Sum of the stated EXPLORER frame and external UPS module weights.
Actual total BASE-unit weight No data The finished product may differ because of connectors, cables and smaller fittings.
Integrated M8 mounting points 8 For mechanically securing accessories and fittings.
Connector sets QS Custom Connectors Set 3 + UPS connector set Included in the BASE assembly.
Complete-system IP rating No data  

Recommended applications

  • With a separately selected battery, backup power for gas boilers, circulation pumps and heating controllers.
  • Smaller critical loads in institutional, industrial or agricultural applications.
  • Routers, modems, network equipment, camera systems and communication devices.
  • Computers, controllers, monitoring systems and smaller technical electronic equipment.
  • Lighting, gate control, security equipment and other loads requiring up to 1000 W continuous power.
  • Applications where pure sine wave 230 V output, AVR or phase-correct supply is important.
Runtime is determined by the selected battery: actual backup time depends on battery capacity, chemistry, permitted depth of discharge, BMS, temperature and condition, as well as UPS losses and load power.

Safety and installation warning

Do not start without a battery: according to the manufacturer’s instructions, the external UPS module must not be started without a connected battery, as this may cause damage.
230 V mains voltage: installation, phase-correct wiring and use with a boiler or building-services system must be checked by a qualified electrician.
Stand-alone output: loads may be connected directly to the two 230 V sockets. The output must not be connected to or backfeed the building’s existing electrical installation.
High-current 12 V system: the battery, cabling, fuses, connectors and, for LiFePO₄ batteries, the BMS rating must be sized for expected continuous and starting current.
Ventilation: the UPS fan and ventilation openings must remain unobstructed. At least 15 cm of free space must be provided around the module.
Moisture and location: no IP rating is specified for the complete system. Use only in a dry, dust-free and well-ventilated area, protected from rain, water, corrosive gases, fuel and flammable materials.
Load limit: even with a suitable battery, the combined continuous 230 V load must not exceed 1000 W. Starting peak power must be considered separately for every load.
Repair and modification: do not open, modify or attempt to repair the UPS module or high-current connections.