Fully assembled EnergonX UPS system
The battery, external UPS module, wheeled chassis and required connection components form one operational unit.
Fully assembled high-capacity 12 V LiFePO₄ UPS system
The EnergonX UPS Tech 12 [A024]-1 is a fully assembled wheeled backup-power system with a LiTime 12.8 V / 320 Ah W190 Smart Bluetooth LiFePO₄ battery and a TECHTRON ZA-TECH-1000-PLUS external UPS module. Nominal battery energy is 4096 Wh / 4.096 kWh, and continuous 230 V output power is up to 1000 W.
Important: the total continuous 230 V load must not exceed 1000 W. Starting surges of motors, pumps, fans and other inductive loads must be checked separately.
The complete English-language user and safety manual for the EnergonX UPS Tech 12 [A024]-1 is available to view and download in PDF format.
Fully assembled 12 V EnergonX UPS system with a wheeled EXPLORER chassis, TECHTRON ZA-TECH-1000-PLUS external UPS module and LiTime 12.8 V / 320 Ah W190 Smart Bluetooth LiFePO₄ battery.
The system stores 4096 Wh, or 4.096 kWh, of nominal battery energy. During mains operation it supplies connected loads and charges the battery; in the event of a mains failure or major voltage deviation, it automatically transfers to battery operation. Continuous 230 V output power is limited to 1000 W.
The battery, external UPS module, wheeled chassis and required connection components form one operational unit.
The LiTime 12.8 V, 320 Ah LiFePO₄ battery stores 4096 Wh of nominal energy.
Suitable for sensitive electronics, control systems, circulation pumps and smaller critical loads.
Typically transfers from mains to battery operation in approximately 4 ms and within a maximum of 8 ms.
The LiTime application displays state of charge, voltage, current, power, cycle count and other battery data.
The four-stage AVR corrects moderate mains deviations, while phase-correct operation supports sensitive boilers and control systems.
| System component | Description | SKU / status |
|---|---|---|
| BASE unit | EnergonX UPS Tech 12 BASE | {EX1400-EXP-12} |
| External UPS module | UPS EXT Tech 1000 / TECHTRON ZA-TECH-1000-PLUS | {EX2310-UPSTech-1000} |
| Battery | LiTime 12 V 320 Ah W190 Smart Bluetooth LiFePO₄ | {EX2200-A024} |
| M8 mounting points | 8 installed points | {EX2100-QBRM8I} |
| Connector set | QS Custom Connectors Set 3 | {EX2100-QBRCC} |
| UPS connector set | UPS connector set accessory | {EX2100-UPSHT120} |
High energy reserve for longer backup-power applications.
Overvoltage, undervoltage, overcurrent, short-circuit and temperature protection.
Real-time battery data and diagnostic information in the LiTime mobile application.
Below 0 °C, the BMS disables charging to protect the cells.
In cold environments, charging can begin only when battery temperature is above 0 °C.
The IP65 rating applies only to the battery, not to the complete assembled system.
The battery is not self-heating. The BMS low-temperature charging protection prevents damage to the LiFePO₄ cells.
The TECHTRON module supplies up to 1000 W continuous 230 V load.
Approximately 1200 W for no more than 30 seconds, after which the UPS may shut down.
Loads connect directly to the two output sockets on the external UPS module.
The built-in three-stage charger can be set to a maximum charging current of 5 A, 10 A, 15 A, 20 A or 30 A. Charging, float, warning and cut-off values must be matched to the LiTime battery requirements.
The 200 A battery BMS could support a higher DC load, but the complete system's continuous 230 V output is limited to 1000 W.
The calculation uses a modern boiler with a maximum electrical consumption of 113 W and a high-efficiency circulation pump with a maximum power of 40 W, for a total continuous load of 153 W.
| Calculation step | Value | Note |
|---|---|---|
| Nominal battery energy | 4096 Wh | 12.8 V × 320 Ah. |
| Assumed usable energy share | 90% | 10% energy reserve remains in the battery. |
| Assumed usable DC energy | 3686 Wh | 4096 Wh × 90%. |
| Assumed UPS efficiency | 88% | Assumption for the example, not a guaranteed value. |
| Estimated usable 230 V energy | approx. 3244 Wh | 3686 Wh × 88%. |
| Combined boiler and pump load | 153 W | 113 W boiler + 40 W pump. |
| Estimated continuous runtime | approx. 21.2 hours | 3244 Wh ÷ 153 W. |
Under the stated assumptions, the system can continuously supply a 113 W boiler and a circulation pump of up to 40 W for approximately 21.2 hours.
Actual runtime depends on load, starting current, battery state of charge, temperature and condition, UPS losses and the configured cut-off voltage. Intermittent or part-load operation may increase real runtime.
The high-capacity battery and external UPS module are integrated into one wheeled system.
Provide stable mechanical attachment and support later professional expansion.
The EnergonX UPS Tech 12 BASE weighs approximately 21.2 kg, and the LiTime battery weighs approximately 25.93 kg. The complete system therefore weighs approximately 47.1 kg.
| Parameter | Data | Note |
|---|---|---|
| SKU | EX1400-EXP-12 [A024]-1 | EnergonX finished-product SKU. |
| System voltage | 12 V / 12.8 V | 12 V LiFePO₄ system. |
| Battery | LiTime 12.8 V / 320 Ah W190 Smart Bluetooth LiFePO₄ | {EX2200-A024} |
| Nominal battery capacity | 320 Ah | Manufacturer data. |
| Nominal stored energy | 4096 Wh / 4.096 kWh | 12.8 V × 320 Ah. |
| Battery BMS | 200 A Smart BMS | Integrated intelligent protection and monitoring. |
| Bluetooth | Bluetooth 5.0 | With LiTime application. |
| Low-temperature charging protection | Yes | Below 0 °C, the BMS disables charging. |
| Self-heating | No | The battery is not self-heating. |
| Battery IP rating | IP65 | Does not apply to the complete system. |
| Battery dimensions | 368 × 189 × 255 mm | Length × width × height. |
| Battery weight | approx. 25.93 kg | Manufacturer data. |
| UPS module | TECHTRON ZA-TECH-1000-PLUS | EnergonX name: UPS EXT Tech 1000. |
| UPS topology | Line-Interactive | Automatic transfer and AVR. |
| Rated apparent power | 1500 VA | Manufacturer data. |
| Continuous active power | up to 1000 W | System output is limited by the UPS module. |
| Short-duration overload | approx. 1200 W, max. 30 seconds | The UPS may then shut down. |
| Output waveform | Pure sine wave | Battery operation. |
| 230 V outputs | 2 earthed sockets | On the external UPS module. |
| Mains-to-battery transfer | typically approx. 4 ms; max. 8 ms | Manufacturer data. |
| Return to mains | typically approx. 2 ms; max. 4 ms | Manufacturer data. |
| AVR | Yes, 4-stage, approx. ±8% | Mains voltage regulation. |
| Fixed phase | Yes | With correct mains wiring. |
| Built-in battery charger | Three-stage intelligent charger | Adjustable for LiFePO₄ parameters. |
| Selectable maximum charging current | 5 A / 10 A / 15 A / 20 A / 30 A | Set to the appropriate value for the battery. |
| Mains input range | approx. 160–270 V AC | Outside this range it may transfer to battery. |
| ECO mode | Yes | Reduced self-consumption. |
| Cold start | Yes | Can start from battery. |
| Protection functions | Overload, output short circuit, mains over/undervoltage, surge, over-temperature, battery deep discharge | Manufacturer data. |
| EXPLORER chassis dimensions | 641 × 485 × 660 mm | EnergonX chassis data. |
| UPS Tech 12 BASE weight | approx. 21.2 kg | Total BASE weight. |
| Complete-system weight | approx. 47.1 kg | BASE + installed LiTime battery. |
| Integrated M8 mounting points | 8 | For mechanical attachment. |
| Connection sets | QS Custom Connectors Set 3 + UPS connector set | Included in the complete system. |
Backup power for gas boilers, circulation pumps and heating controls.
Smaller critical loads, controls, monitoring systems and technical electronics.
Routers, modems, network devices, camera systems and gate controls.
Starting surges of every motor-driven or inductive load must be checked separately.
Installation, phase-correct wiring and use with boilers or building-services equipment must be checked by a qualified electrician.
Connect loads directly to the two 230 V sockets. Do not connect or back-feed the output into the building's electrical installation.
Disconnect battery-to-UPS connections only with the system de-energised. Cables, fuse protection and connectors must be correctly sized.
The battery is not self-heating. Below 0 °C, the BMS disables charging; do not bypass this protection.
Keep the UPS fan and vents clear and provide at least 15 cm of free space around the module.
No IP rating is specified for the complete system. Use in a dry, dust-free and well-ventilated location.
The total continuous 230 V load must not exceed 1000 W. Starting surges must be considered separately.
Do not open, modify or repair the UPS module, battery or high-current connections yourself.