Fully assembled 12 V UPS base unit without battery

The EnergonX UPS SOHO 12 BASE is a mobile backup-power base unit prepared for battery installation and equipped with an SPS SOHO SH1000 external UPS/inverter. Its rated output is 1000 VA / 800 W, and in battery operation it provides a sine-wave output with a 6 ms transfer time.

12 V DC 1000 VA / 800 W Sine wave in battery mode 6 ms transfer 10 A / 20 A charging UPS / inverter mode 8 M8 mounting points Without battery

Main features

  • BASE version: includes the EXPLORER chassis, the SPS SOHO SH1000 unit and the required EnergonX connection and installation components, but does not include a battery.
  • Battery-mode output: 220 V AC ±10%, 50 Hz ±1 Hz, sine-wave output.
  • Charging: 13.8 V ±0.3 V charging voltage, with switch-selectable 10 A or 20 A charging current.
  • Compatible battery: a correctly sized conventional 12 V lead-acid or AGM battery.
  • Not compatible: must not be used with a LiFePO₄ battery.
  • Protections: overload, short-circuit and overheating protection, plus a battery circuit breaker.

Important: without a battery, the unit cannot be used as an operational backup power source.

Brand:
EnergonX
Product code:
{EX1412-EXP-12}
191.814 HUF
Netto price: 151.035 HUF
Piece (pc)
Piece (pc)

EnergonX UPS SOHO 12 BASE

Fully assembled 12 V UPS base unit without battery, with a mobile EXPLORER chassis and an SPS SOHO SH1000 external UPS/inverter.

After a suitable battery has been installed, the system supplies the connected load and charges the battery during mains operation. In the event of a mains failure, it switches to battery operation with a 6 ms transfer time. The rated output is 1000 VA / 800 W.

What is included in the BASE version?

EXPLORER mobile chassis

Mobile Qbrick System ONE Cart 2.0 RED Ultra HD Custom base with internal space prepared for battery installation.

SPS SOHO SH1000

12 V external UPS/inverter with 1000 VA apparent power and 800 W rated active power.

Installation and connection system

Eight integrated M8 mounting points, QS Custom Connectors Set 3 and a dedicated UPS connector set.

The battery is not included in the BASE version

The product becomes an operational EnergonX UPS system only after a suitable 12 V battery has been installed, polarity and fuse protection have been checked, and the correct 10 A or 20 A charging current has been selected.

Main advantages of the configuration

1000 VA / 800 W

With a suitable battery, it can be used for boilers, circulation pumps, control systems and smaller critical loads.

Sine-wave battery output

In battery operation, it provides 220 V AC ±10% output voltage, 50 Hz ±1 Hz frequency and a sine-wave output.

6 ms transfer time

In the event of a mains failure, it switches quickly to battery operation.

10 A / 20 A charging current

The charging current is switch-selectable and can be set according to the battery manufacturer's specification.

UPS and inverter operating modes

The front-panel switch selects UPS or inverter mode to suit the required mains-input range.

Modular EXPLORER design

The mobile chassis, eight M8 mounting points and detachable connection system simplify transport and maintenance.

Which batteries can be used?

12 V lead-acid or AGM battery

A correctly sized conventional 12 V lead-acid or AGM battery may be used if it physically fits in the EXPLORER chassis, supports a charging voltage of 13.8 V ±0.3 V and permits the selected 10 A or 20 A charging current.

LiFePO₄ batteries must not be used

This SOHO 12 BASE version is not suitable for charging or operating with a LiFePO₄ battery.

Main technical data

On mobile devices, the table can be scrolled horizontally.
Parameter Data Note
Product name EnergonX UPS SOHO 12 BASE Fully assembled 12 V UPS base unit without battery.
Part number EX1412-EXP-12 EnergonX product identifier.
System voltage 12 V DC For one external 12 V battery.
Integrated battery None A suitable battery must be selected separately.
External UPS / inverter SPS SOHO SH1000 Included in the BASE version.
Rated apparent power 1000 VA Manufacturer data.
Rated active power 800 W Manufacturer data.
Power factor 0.8 Manufacturer data.
Rated mains input 220 V AC / 50 Hz Manufacturer data.
Input range in inverter mode 120–300 V AC Manufacturer data.
Input range in UPS mode 145–285 V AC Manufacturer data.
Input frequency range 38–70 Hz Manufacturer data.
Battery-mode output voltage 220 V AC ±10% Manufacturer data.
Battery-mode output frequency 50 Hz ±1 Hz Manufacturer data.
Battery-mode output waveform Sine wave Manufacturer data.
Transfer time 6 ms Manufacturer data.
Charging voltage 13.8 V ±0.3 V Manufacturer data.
Selectable charging current 10 A or 20 A Switch-selectable.
UPS / inverter mode Selectable Via front-panel switch.
Protections Overload, short circuit, overheating Manufacturer data.
Battery circuit breaker Yes On the rear panel.
Status indications Mains, battery operation, charging, charge level, battery status, fault Front-panel LED indicators.
Noise level 55 dB at 1 metre Manufacturer data.
Operating temperature 0–40 °C Manufacturer data.
Operating humidity 20–95%, non-condensing Manufacturer data.
EXPLORER chassis external dimensions 641 × 485 × 660 mm EnergonX data.
SH1000 unit dimensions 313 × 295 × 189 mm Width × depth × height.
EXPLORER chassis weight approx. 10.2 kg EnergonX data.
SH1000 unit weight 15.0 kg Manufacturer data.
Integrated M8 mounting points 8 pcs For mechanical mounting of accessories.
Connector sets QS Custom Connectors Set 3 + UPS connector set Included in the BASE assembly.

Recommended applications

Heating systems

With a suitable battery, for backup power to gas boilers, circulation pumps and heating control systems.

Institutional and technical loads

Backup power for smaller critical loads, control systems, monitoring systems and technical electronic equipment.

Communication and security technology

Power supply for routers, modems, network devices, camera systems, gate controls and communication equipment.

Up to 800 W continuous load

The starting surge of the connected loads must always be considered separately.

Runtime is determined by the selected battery

Actual backup runtime is affected by battery capacity, chemistry, permitted depth of discharge, BMS, temperature and condition, as well as inverter losses and the power consumption of the connected loads.

Safety and installation information

Do not start without a battery

An external battery is required for correct inverter operation. Before commissioning, check the system voltage, polarity, fuse protection and the tightness of all connections.

230 V mains voltage

Installation and use with building-services equipment must be checked by a qualified electrician. Opening the enclosure presents an electric-shock hazard.

Stand-alone output

The load must be connected directly to the inverter output. The output must not be connected to or back-feed the building's existing electrical installation.

Ventilation and environment

Use only indoors in a dry, dust-free and well-ventilated location. Keep the fan and ventilation openings unobstructed, and do not allow the unit to come into contact with liquids.

Not for safety-critical life-protection applications

Not suitable for direct use with life-support medical equipment, lifting equipment, traffic-control systems, aviation systems or other safety-critical applications.