Fully assembled EnergonX UPS system
The battery, UPS/inverter, mobile chassis and required connection components form one operational unit.
Fully assembled 12 V AGM UPS system
The EnergonX UPS SOHO 12 [A010]-1 is a fully assembled mobile backup-power system with a Green Cell 12 V / 200 Ah AGM VRLA battery and an SPS SOHO SH1000 external UPS/inverter. Its nominal battery energy is 2400 Wh / 2.4 kWh, and its continuous 230 V output is up to 800 W.
Important: the battery manufacturer's specified short-circuit current is 2700 A. Short-circuiting the terminals can cause serious injury, arcing and fire.
Fully assembled 12 V EnergonX UPS system with battery, mobile EXPLORER chassis, SPS SOHO SH1000 external UPS/inverter and Green Cell 12 V / 200 Ah AGM VRLA battery.
The system stores 2400 Wh, or 2.4 kWh, of nominal battery energy. During mains operation it supplies the connected load and charges the battery; in the event of a mains failure, it switches to battery operation with a 6 ms transfer time. The continuous 230 V output limit is 800 W.
The battery, UPS/inverter, mobile chassis and required connection components form one operational unit.
The Green Cell 12 V, 200 Ah AGM battery stores 2400 Wh of nominal energy.
Suitable for boilers, circulation pumps, control systems and smaller critical loads.
In battery operation, it provides 220 V AC ±10% output voltage, 50 Hz ±1 Hz frequency and a sine-wave waveform.
In the event of a mains failure, it switches quickly to battery operation.
Sealed design, does not require electrolyte top-up, and is intended for float and cyclic service.
| System component | Designation | Part number / status |
|---|---|---|
| Chassis | CHASSIS – EXPLORER | {EX-EXP-VÁZ} |
| External UPS / inverter | SPS SOHO SH1000 | Included in the finished product |
| Battery | 12 V / 200 Ah AGM battery for UPS applications | {EX2200-A010} |
| M8 mounting points | Integrated, 8 pcs | {EX2100-QBRM8I} |
| Connector set | QS Custom Connectors Set 3 | {EX2100-QBRCC} |
| UPS connector set | Accessory – UPS connector set | {EX2100-UPSHT120} |
200 Ah capacity and 2400 Wh nominal energy storage at 12 V system voltage.
The electrolyte is absorbed in a glass-fibre separator, so no liquid top-up is required.
For stable high-current mechanical and electrical connection.
The IP54 rating applies only to the battery, not to the complete assembled system.
Value according to the manufacturer's specification; actual service life depends on operating mode, depth of discharge and temperature.
The substantial weight of the high-capacity AGM battery must be considered during transport and installation.
Accidental short-circuiting of the battery terminals can cause severe burns, arcing, fire and melting of the connectors. Appropriate fuse protection, terminal protection and insulated tools are mandatory.
The Green Cell battery's float-service charging voltage is 13.5–13.8 V, while the SPS SOHO SH1000 charging voltage is 13.8 V ±0.3 V. Because these ranges overlap, the system is primarily suited to standby UPS and float-service operation.
For cyclic charging, Green Cell specifies 14.5–14.9 V. The integrated charger of the SH1000 does not provide this range, so frequent deep-discharge cyclic use requires a separate suitable charging solution.
The 20 A setting corresponds to approximately 0.1 C for a 200 Ah battery and remains well below the manufacturer's 60 A maximum. The 10 A setting is gentler but may result in approximately twice the charging time.
The charging current may change during the process, and an AGM battery draws progressively less current near the end of charging. Actual full charging time may therefore be longer than the simple quotient of nominal capacity and charging current.
The SPS SOHO SH1000 has 1000 VA rated apparent power and 800 W rated active power.
In battery operation, it provides 50 Hz ±1 Hz frequency and a sine-wave output waveform.
The mains-input range is 120–300 V AC in inverter mode and 145–285 V AC in UPS mode.
Overload, short-circuit and overheating protection, battery circuit breaker, and front-panel indicators for mains, charging, battery and fault status.
The following illustrative calculation assumes a modern condensing boiler with a maximum electrical consumption of 113 W and a high-efficiency circulation pump with a maximum consumption of 40 W, for a total continuous load of 153 W.
| Calculation step | Value | Note |
|---|---|---|
| Nominal battery energy | 2400 Wh | 12 V × 200 Ah. |
| Battery-friendly depth of discharge | 50% | To help preserve AGM battery service life. |
| Assumed usable DC energy | 1200 Wh | 2400 Wh × 50%. |
| Assumed inverter efficiency | 80% | Assumption for the example calculation, not a guaranteed value. |
| Estimated useful 230 V energy | 960 Wh | 1200 Wh × 80%. |
| Combined boiler and pump load | 153 W | 113 W boiler + 40 W pump. |
| Estimated battery-friendly runtime | approx. 6.3 hours | 960 Wh ÷ 153 W. |
At 50% depth of discharge and an assumed inverter efficiency of 80%, the system can continuously supply a 113 W boiler and a circulation pump of up to 40 W for approximately 6.3 hours.
The actual capacity of an AGM battery depends on discharge current, temperature, age and condition. A greater depth of discharge may provide longer runtime on a single cycle but can accelerate battery wear. Intermittent or partial-load operation of the boiler and pump may increase actual runtime.
The 54 kg battery and the SPS SOHO SH1000 unit are installed in one system. Eight integrated M8 mounting points provide stable mechanical mounting.
The QS Custom Connectors Set 3 and the dedicated UPS connector set are part of the finished system's connection arrangement.
The 54 kg battery, the 15 kg UPS/inverter and the EXPLORER chassis form one mobile system. Whenever possible, move the system on its wheeled chassis; manual lifting requires multiple people or suitable lifting equipment.
| Parameter | Data | Note |
|---|---|---|
| Part number | EX1412-EXP-12[A010]-1 | EnergonX finished-product identifier. |
| System voltage | 12 V DC | With one 12 V AGM battery. |
| Battery | Green Cell AGM12V200AH-J | Sealed, maintenance-free VRLA AGM. |
| Nominal battery capacity | 200 Ah | Manufacturer data. |
| Nominal stored energy | 2400 Wh / 2.4 kWh | 12 V × 200 Ah. |
| Battery float-service charging voltage | 13.5–13.8 V | Manufacturer data. |
| Battery cyclic charging voltage | 14.5–14.9 V | Manufacturer data. |
| Maximum battery charging current | 60 A | Manufacturer data. |
| Battery short-circuit current | 2700 A | Extremely high short-circuit current. |
| Battery terminal | M8 threaded terminal | Manufacturer data. |
| Battery IP rating | IP54 | Does not apply to the complete system. |
| Battery dimensions | 240 × 522 × 226 mm | Overall height including terminals. |
| Battery weight | 54.0 kg | Manufacturer data. |
| External UPS / inverter | SPS SOHO SH1000 | Included in the finished product. |
| Rated apparent power | 1000 VA | Manufacturer data. |
| Rated active power | 800 W | Manufacturer data. |
| Power factor | 0.8 | Manufacturer data. |
| Battery-mode output voltage | 220 V AC ±10% | Manufacturer data. |
| Battery-mode output frequency | 50 Hz ±1 Hz | Manufacturer data. |
| Battery-mode output waveform | Sine wave | Manufacturer data. |
| Transfer time | 6 ms | Manufacturer data. |
| UPS charging voltage | 13.8 V ±0.3 V | Compatible with the float-service range. |
| Selectable charging current | 10 A or 20 A | 20 A is recommended for this capacity. |
| Protections | Overload, short circuit, overheating | Manufacturer data. |
| Noise level | 55 dB at 1 metre | Manufacturer data. |
| Operating temperature | 0–40 °C | UPS unit. |
| Operating humidity | 20–95%, non-condensing | UPS unit. |
| EXPLORER chassis external dimensions | 641 × 485 × 660 mm | EnergonX chassis data. |
| SH1000 unit dimensions | 313 × 295 × 189 mm | Width × depth × height. |
| EXPLORER chassis weight | approx. 10.2 kg | EnergonX chassis data. |
| SH1000 unit weight | 15.0 kg | Manufacturer data. |
| Integrated M8 mounting points | 8 pcs | For mechanical mounting. |
Backup power for gas boilers, circulation pumps and heating control systems.
For supplying smaller critical loads, control systems, monitoring systems and technical electronic equipment.
Power supply for routers, modems, camera systems, gate controls and communication equipment.
The starting surge of motors, pumps, fans and transformer-based loads must be checked separately.
Installation and use with building-services equipment must be checked by a qualified electrician.
The load must be connected directly to the inverter output. The output must not be connected to or back-feed the building's electrical installation.
Fuse protection, cables, connectors and mechanical protection must be designed with the battery's 2700 A short-circuit current in mind.
Use only indoors in a dry, dust-free and well-ventilated location. Keep the fan and ventilation openings unobstructed.
The inverter's protective earth connection must be connected correctly.
Not suitable for direct use with life-support medical equipment, lifting equipment, traffic-control systems, aviation systems or other safety-critical applications.